Blog

TURBOCOR COMPRESSOR REPLACEMENT

17 Jun TURBOCOR COMPRESSOR REPLACEMENT

ENJOYING THIS POST? Share it with your colleagues Share on linkedin LinkedIn Share on facebook Facebook Share on twitter Twitter TURBOCOR COMPRESSOR REPLACEMENT We carried out a Turbocor Compressor Replacement for one of our customers, all in-house. We found a Turbocor TT350 with failed Magnetic Bearings. We quoted the Supply of The Turbocor Replacement Compressor,...

Read More
The_Olo_Team

04 Jun ROSS CHILLER CONTROLS RETROFIT

ENJOYING THIS POST? Share it with your colleagues Share on linkedin LinkedIn Share on facebook Facebook Share on twitter Twitter ROSS CHILLER CONTROLS RETROFIT A site in Central London had two Ross Comfort Cooling Water Chillers with failed controllers offering no cooling to some very posh flatts. We had all the parts in stock,...

Read More
Chiller-Flow-Recommission

27 May CHILLER FLOW RECOMMISSION

ENJOYING THIS POST? Share it with your colleagues Share on linkedin LinkedIn Share on facebook Facebook Share on twitter Twitter CHILLER FLOW RECOMMISSION We attended site for numerous Low Temp Chilled Water Trips on 3 Carrier Chillers of various capacities, all connected to a Low Loss Header with a Variable Secondary Chilled Water Flow;...

Read More
LEAKY FRANKEN-FRIDGE

17 May LEAKY FRANKEN-FRIDGE

ENJOYING THIS POST? Share it with your colleagues Share on linkedin LinkedIn Share on facebook Facebook Share on twitter Twitter LEAKY FRANKEN-FRIDGE We attended site to a Work Laboratory Cold Room for a large Pharmaceutical Company. The standby Chiller Unit had kicked in with our unit out on Low Pressure Safety. Investigations found a...

Read More
Plate Heat Exchanger

14 Apr PLATE HEAT EXCHANGER

ENJOYING THIS POST? Share it with your colleagues Share on linkedin LinkedIn Share on facebook Facebook Share on twitter Twitter Plate Heat Exchanger We attended a callout to a chiller in alarm, on arrival we found a system short of refrigerant. We carried out a full pressure test and could not find a leak,...

Read More
BETTER THAN MANUFACTURER CONTROLS UPGRADE

29 Mar BETTER THAN MANUFACTURER CONTROLS UPGRADE

ENJOYING THIS POST? Share it with your colleagues Share on linkedin LinkedIn Share on facebook Facebook Share on twitter Twitter Better than Manufacturer Controls Upgrade A Climaveneta Chiller had a failed controller which due to unsupported hardware required the replacement of the Master & Slave Controllers at great expense, so much so we costed...

Read More
THE IMPORTANCE OF GOOD HEAT EXCHANGE

27 Nov THE IMPORTANCE OF GOOD HEAT EXCHANGE

ENJOYING THIS POST? Share it with your colleagues Share on linkedin LinkedIn Share on facebook Facebook Share on twitter Twitter THE IMPORTANCE OF GOOD HEAT EXCHANGE A site where the Cooling Tower’s water was in a horrendous state due to a Total Dissolved Solids Controller being so out of kilter, it never carried out...

Read More
2 - INVERTER PACK

05 Nov BITZER INVERTER SCREW COMPRESSOR COMMISSIONING

ENJOYING THIS POST? Share it with your colleagues Share on linkedin LinkedIn Share on facebook Facebook Share on twitter Twitter BITZER INVERTER SCREW COMPRESSOR COMMISSIONING We have had the absolute pleasure in commissioning some Bitzer Inverter Screw compressors used in the Aermec Chiller range. Bitzer’s Service Tool; BEST is a brilliant interface to the...

Read More
Lowering Refrigerant Leak Rates 1

26 Oct LOWERING REFRIGERANT LEAK RATES

ENJOYING THIS POST? Share it with your colleagues Share on linkedin LinkedIn Share on facebook Facebook Share on twitter Twitter  LOWERING REFRIGERANT LEAK RATESThere seems to be a growing trend with modern Chiller Manufacturers to directly mount Pressure Relief Valves to suction and discharge lines. More-over to actually mount Dual Port Pressure Relief...

Read More